Publication date: Available online 16 November 2018
Source: Journal of Cranio-Maxillofacial Surgery
Author(s): António Ramos, Luis M. Gonzalez-Perez, Pedro Infante-Cossio, Michel Mesnard
Summary
Purpose
The purpose of this study is to pre-validate a novel implant concept, and to compare the behavior of the mandibular condyle against a commercial Biomet implant in an ex vivo model and present results of the first cadaveric studies.
Materials and Methods
Three experimental cadaveric condyles were tested under three conditions: one intact, another with the Biomet model, and one with the innovative concept. The condyle was tested with a reaction of 300N in all situations and the principal strains were measured. Before the geometry of the cadaveric condyle was reconstructed from a microCT scan, and a finite element model was created. Finally, a procedure was carried out with the new implant by two expert surgeons on a two cadaveric head model.
Results
In vitro the mandible condyle presents a linear behavior until maximum load. The strain measured with Biomet implant indicates a strain shielding effect in the proximal region, inducing bone loss in the long term. The lingual side of the Biomet implanted condyle presents an increase of +44% in strain.
Conclusion
The new concept was evaluated and showed a similar behavior to the intact model, and better behavior than the Biomet. The innovative concept proves that it is possible to avoid screws for a TMJ fixation and improve the TMJ alloplastic behavior.
from OroFacial via a.sfakia on Inoreader https://ift.tt/2PyskfI
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.