Abstract
Objectives
A postprocessing technique termed 3D true-phase polarity recovery with independent phase estimation using three-tier stacks based region growing (3D-TRIPS) was developed, which directly reconstructs phase-sensitive inversion-recovery images without acquisition of phase-reference images. The utility of this technique is demonstrated in myocardial late gadolinium enhancement (LGE) imaging.
Materials and methods
A data structure with three tiers of stacks was used for 3D-TRIPS to directly achieve reliable region growing for successful background-phase estimation. Fifteen patients undergoing postgadolinium 3D phase-sensitive inversion recovery (PSIR) cardiac LGE magnetic resonance imaging (MRI) were recruited, and 3D-TRIPS LGE reconstructions were compared with standard PSIR. Objective voxel-by-voxel comparison was performed. Additionally, blinded review by two radiologists compared scar visibility, clinical acceptability, voxel polarity error, or groups and blurring.
Results
3D-TRIPS efficiently reconstructed postcontrast phase-sensitive myocardial LGE images. Objective analysis showed an average 95% voxel-by-voxel agreement between 3D-TRIPS and PSIR images. Blinded radiologist review demonstrated similar image quality between 3D-TRIPS and PSIR reconstruction.
Conclusion
3D-TRIPS provided similar image quality to PSIR for phase-sensitive myocardial LGE MRI reconstruction. 3D-TRIPS does not require acquisition of a reference image and can therefore be used to accelerate phase-sensitive LGE imaging.
from # All Medicine by Alexandros G. Sfakianakis via alkiviadis.1961 on Inoreader http://ift.tt/2j2ns3t